MinIPAQ C230

Universal 2-wire transmitter with wireless communication

MinIPAQ C230 is a universal, unisolated, 2-wire head-mounted transmitter for temperature measurements and other measurement applications.
It’s robust design and high quality provide good performance and accuracy even under harsh conditions.
The transmitter accepts inputs from several types of resistance thermometers (RTDs), thermocouple sensors (TCs), and linear resistance and mV signals.
Configuration of the transmitter is easily done with the INOR Connect smartphone app, either wirelessly via NFC or via a connected Bluetooth® modem.
Configuration can also be done via a PC with the Windows programme ConSoft.

  • Input for resistance thermometers (RTD) and resistance in 2-, 3- and 4-wire connection
  • Input for thermocouple (TC) and mV signals
  • Fits in DIN Form B or larger connection heads
  • Configuration via PC, NFC or Bluetooth® without external power supply
  • Sensor error correction and system error correction (sensor+transmitter) for highest overall accuracy
  • Runtime counter – hour counter for elapsed operating time
  • Robust design tested for 10 g vibration
  • High security – password protection for changes
  • Possible to configure and monitor the transmitter remotely via a connected Bluetooth® modem

Teknisk specifikation

Type Universal digital head-mounted 2-wire signal transmitter
Input Resistance (RTD), Thermocouples (TC), mV and Ω
Input Resistance, 2-, 3-, 4-wire connection Pt10 to Pt1000, Ni100, Ni120, Ni1000
Input Thermocouples Type B, C, D, E, J, K, N, R, S, T
Input mV -10 to +1000 mV
Input Resistance, 2-, 3-, 4-wire connection 0 to 4000 Ω (0-2000 ohm for 2-wire coupling)
Output 4-20 mA, (temperature linear RTD and TC) , 2-wire loop powered
Output signal and sensor failure According to NAMUR NE43
Galvanic isolation No, unisolated
Power supply, polarity protected 8 to 36 VDC
Typical accuracy, (RTD) Max. of ±0.15 K or ±0.15 % of span
Typical accuracy, TC type J and K Max. of ±0.5 K or ±0.25 % of span, ±1 K (CJC)
Long-term drift Maximum ±0,05% of span per year
Vibration IEC 60068-2-6, 10 g
EMC According to standards EN 61326-1 and EN 61326-2-3
RoHS Complies with the requirements of RoHS-directive
Configuration ConSoft Windows software or INOR Connect smartphone app
Wireless configuration NFC and Bluetooth® *
Mounting In connection-head according to DIN EN 50446 form B or larger

* Bluetooth® communication is only supported with ICON-BT

Dokument

Request a quote

  • For example approvals and configuration
  • This field is for validation purposes and should be left unchanged.